A lab report is a list of names, numbers and units, sometimes with a flag next to anything over a limit. EPA says your results should include the concentration of each substance tested and may say whether it exceeds a national primary or secondary drinking water standard.[1] Here is how to make sense of it.
1. Get the units straight
| Unit | Means | Typical use |
|---|---|---|
| mg/L (milligrams per liter) | Equal to ppm (parts per million)[2] | Iron, manganese, nitrate, hardness, TDS |
| µg/L or ug/L (micrograms per liter) | 1/1,000 of a mg/L; reported as ppb (parts per billion), the unit USGS describes as "used to measure extremely small concentrations"[3] | Lead, arsenic, uranium |
| ng/L (nanograms per liter) | Equal to ppt (parts per trillion), as EPA expresses PFAS limits[4] | PFAS |
| gpg (grains per gallon) | Hardness only; about 17 mg/L (ppm) as calcium carbonate[2] | Hardness |
| Colonies (or CFU) per 100 mL, or Present/Absent | Bacteria counts in 100 mL of water; "present" means at least one bacterium was found in 100 mL[5] | Coliform, E. coli |
| pCi/L (picocuries per liter) | Radioactivity | Radium, gross alpha[6] |
Quick conversions. 0.010 mg/L = 10 µg/L = 10 ppb. 0.000004 mg/L = 4 ng/L = 4 ppt. To turn mg/L of hardness into gpg, divide by about 17 (so 171 mg/L is about 10 gpg). Watch the unit before comparing a number to a limit: a lab that reports arsenic as 8 ppb is reporting 0.008 mg/L.
2. Know which kind of limit you're comparing to
- MCL (maximum contaminant level): the legally enforceable limit for public water systems under the National Primary Drinking Water Regulations, based on health risk, treatment feasibility and cost.[6][7] Some contaminants, such as lead and copper, use a "treatment technique" with an action level instead.[6]
- MCLG (goal): the non-enforceable health goal; for some contaminants it is zero.[6]
- SMCL (secondary standard): a non-enforceable guideline for 15 contaminants that affect taste, color, odor, staining or equipment. EPA says these "are not considered to present a risk to human health at the SMCL."[7]
Private wells are not legally bound by any of these,[8] but EPA points well owners to the MCL list as the reference when a lab doesn't compare results for you,[1] and Penn State Extension describes the standards as guidelines for managing private supplies.[9]
3. Health-based limits (primary standards) for common well and tap concerns
| Contaminant | MCL or action level | MCLG | Common sources (per EPA) |
|---|---|---|---|
| Total coliforms (incl. E. coli) | Public-system rule: 5.0% of samples. For drinking water generally, Penn State notes the standard is that no coliform bacteria be present[5] | Zero | Naturally present in the environment; fecal coliforms and E. coli come from human and animal fecal waste |
| Nitrate (as nitrogen) | 10 | 10 | Fertilizer runoff; septic systems, sewage; natural deposits |
| Nitrite (as nitrogen) | 1 | 1 | Same as nitrate |
| Arsenic | 0.010 | 0 | Natural deposits; orchard runoff; glass and electronics waste |
| Lead | Action level 0.015 (treatment technique); revised to 0.010 from Nov. 1, 2027 | Zero | Corrosion of household plumbing; natural deposits |
| Copper | Action level 1.3 (treatment technique) | 1.3 | Corrosion of household plumbing; natural deposits |
| Fluoride | 4.0 | 4.0 | Water additive; natural deposits; fertilizer and aluminum factories |
| Barium | 2 | 2 | Drilling wastes; metal refineries; natural deposits |
| Uranium | 30 µg/L | Zero | Natural deposits |
| Radium 226 + 228 (combined) | 5 pCi/L | Zero | Natural deposits |
| Benzene | 0.005 | Zero | Factories; gas storage tanks and landfills |
| PFOA / PFOS | 4.0 ppt each (0.0000040 mg/L) | Zero | Industrial discharge, certain consumer products, certain firefighting activities |
Values from EPA's National Primary Drinking Water Regulations table.[6] PFAS rules are changing: in May 2026 EPA proposed keeping the PFOA and PFOS limits with an option to extend compliance to 2031, and rescinding the limits for PFHxS, PFNA, HFPO-DA (GenX) and the Hazard Index mixture.[4] We will update this table as rules are finalized.
For nitrate, EPA warns that infants below six months who drink water above the MCL "could become seriously ill and, if untreated, may die."[6] If any result exceeds a health standard, EPA says to contact your public health department and retest to confirm.[1]
4. Nuisance limits (secondary standards)
| Contaminant | SMCL | What you notice above it |
|---|---|---|
| Aluminum | 0.05 to 0.2 mg/L | Colored water |
| Chloride | 250 mg/L | Salty taste |
| Color | 15 color units | Visible tint |
| Copper | 1.0 mg/L | Metallic taste; blue-green staining |
| Corrosivity | Non-corrosive | Metallic taste; corroded pipes and fixture staining |
| Fluoride | 2.0 mg/L | Tooth discoloration |
| Foaming agents | 0.5 mg/L | Frothy, cloudy; bitter taste; odor |
| Iron | 0.3 mg/L | Rusty color; sediment; metallic taste; reddish or orange staining |
| Manganese | 0.05 mg/L | Black to brown color; black staining; bitter metallic taste |
| Odor | 3 threshold odor number | "Rotten-egg," musty or chemical smell |
| pH | 6.5 to 8.5 | Low: bitter metallic taste, corrosion. High: slippery feel, soda taste, deposits |
| Silver | 0.1 mg/L | Skin discoloration; graying of the white of the eye |
| Sulfate | 250 mg/L | Salty taste |
| Total dissolved solids | 500 mg/L | Hardness; deposits; colored water; staining; salty taste |
| Zinc | 5 mg/L | Metallic taste |
Values and effects from EPA.[7] Note that hardness has no federal standard at all; it is classified on a scale instead (see Hard water: test your hardness, then decide if you need a softener).[10]
5. Turn the report into a treatment plan
- Health items first. Bacteria, nitrate/nitrite, arsenic, lead or other primary contaminants over the limit: call your local health department before buying anything, and confirm with a retest.[1]
- Check what each system is certified for. Match each problem to a system type certified to the relevant NSF/ANSI standard: 42 for aesthetic issues such as chlorine taste, 53 for health-effect contaminants, 44 for softeners, 55 for UV, 58 for reverse osmosis, 62 for distillers.[11]
- Treat in the right order. Some problems interfere with treatment for others. For example, oxidized iron fouls softener resin and hardness can scale a UV sleeve.[2][5]
- Retest after installing to confirm the system is working.
Frequently asked questions
Is ppm the same as mg/L?
For drinking water, yes. Penn State Extension notes that parts per million is equal to milligrams per liter (mg/L).
How many mg/L is one grain per gallon?
Approximately 17 mg/L (ppm) of calcium carbonate, according to Penn State Extension. Grains per gallon is used only for hardness.
What is the difference between an MCL and a secondary standard?
An MCL is a legally enforceable limit for public water systems, set to protect health. A secondary standard (SMCL) is a non-enforceable guideline for taste, color, odor and staining; EPA says those contaminants are not considered a health risk at the SMCL.
My well is not a public system. Do MCLs apply to me?
Not legally. Private wells are not regulated under the Safe Drinking Water Act, but EPA points well owners to the MCL list for reference when reading results, and Penn State notes these standards are useful guidelines for private supplies.
Sources
- Protect Your Home's Water — U.S. EPA (accessed November 18, 2026)
- Water Softening — Penn State Extension (accessed November 18, 2026)
- Water Science Glossary — U.S. Geological Survey Water Science School (accessed November 18, 2026)
- Per- and Polyfluoroalkyl Substances (PFAS): Final PFAS National Primary Drinking Water Regulation — U.S. EPA (accessed November 18, 2026)
- Coliform Bacteria — Penn State Extension (accessed November 18, 2026)
- National Primary Drinking Water Regulations — U.S. EPA (accessed November 18, 2026)
- Secondary Drinking Water Standards: Guidance for Nuisance Chemicals — U.S. EPA (accessed November 18, 2026)
- Private Drinking Water Wells — U.S. EPA (accessed November 18, 2026)
- Iron and Manganese in Private Water Systems — Penn State Extension (accessed November 18, 2026)
- Hardness of Water — U.S. Geological Survey Water Science School (accessed November 18, 2026)
- NSF Standards for Water Treatment Systems — NSF (accessed November 18, 2026)